Thứ Tư, 15 tháng 2, 2012

DFT-700-M Hand-held Digital Thermo-hygrometer | Shinko Vietnam

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
Hand-held Digital Thermo-hygrometer
DFT-700-M
DFT-700-M_photo


Features

Up to 10 points of data can be memorized on board

Backlight makes data checking easy wherever you are

Powered by 2 AA alkaline batteries (LR6).(200 hours of continuous use)

IP65 structure (for the front panel) allows usage in harsh environments where the device is exposed to water-splashes or dust.

Safety standards: CE


Spec

Spec
InputThermocouple, RTD, Exclusive hygrothermo sensor
Indicating accuracyThermocouple: Within 0.2%FS1digit
RTD: Within 0.1%FS1digit
Hygrothermo sensor; Within 0.3 (%RH)
Action methodDouble integration method
Sampling period0.4sec
Power supply3V DC size AA alkaline battery (2 pcs)
Battery life200 hours in continuous duty without using backlight
Dust-proof, drip-proofIP65 for the front panel

Exclusive sensors
Thermocouple (K)
PCE-701Thermocouple_PCE-701For measuring
general surface
temperature
0 to 400
PCE-702Thermocouple_PCE-702For measuring a curved surface temperature0 to 400
PCE-704Thermocouple_PCE-704For measuring
temperature of
interiors of objects
and liquids
0 to 400
PCE-706Thermocouple_PCE-706For measuring
temperature of
interiors of objects
and liquids
0 to 400
PCE-707Thermocouple_PCE-707For measuring
general surface
temperature
0 to 400
PCE-707LThermocouple_PCE-707LFor measuring
general surface
temperature
0 to 400
PCE-H7Thermocouple_PCE-H7PCE-707
PCE-707L
(for exchange)
0 to 400
PCE-709Thermocouple_PCE-709For measuring
temperature of
interiors of objects
and liquids
0 to 400
PCE-700MThermocouple_PCE-700MFor measuring
surface temperature
of molds, etc.
(Magnet type)
0 to 300

RTD (Pt100)
PCR-701RTD_PCR-701For measuring
temperature of
interiors of objects
and liquids
0 to 400

Hygrothermo transmitter
THD-700-PHygrothermo transmitter_THD-700-PTemperature: 0 to 50
Humidity: 20 to 90%RH

Conversion plug
PCE-CP7Conversion_plug_PCE-CP7Temperature sensor for the DFT-600(thermocouple K) can be used.